EasySep™ Human Naïve B Cell Isolation Kit

9-Minute cell isolation kit using immunomagnetic negative selection
Catalog #
17254_C
9-Minute cell isolation kit using immunomagnetic negative selection
From: 825 USD
New look, same high quality and support! You may notice that your instrument or reagent packaging looks slightly different from images displayed on the website, or from previous orders. We are updating our look but rest assured, the products themselves and how you should use them have not changed. Learn more
Required Products
  1. EasySep™ Magnet
    EasySep™ Magnet

    Magnet for column-free immunomagnetic separation

  2. EasySep™ Buffer
    EasySep™ Buffer

    Cell separation buffer

Overview

The EasySep™ Human Naïve B Cell Isolation Kit is designed to isolate naïve B cells from fresh or previously frozen peripheral blood mononuclear cells or washed leukapheresis samples by immunomagnetic negative selection. The EasySep™ procedure involves labeling unwanted cells with antibody complexes and magnetic particles. The magnetically labeled cells are separated from the untouched desired cells by using an EasySep™ magnet and simply pouring or pipetting the desired cells into a new tube. This product can be used in place of the EasySep™ Human Naïve B Cell Enrichment Kit (Catalog #19254) for even faster cell isolations.
Advantages
• Fast, easy-to-use and column-free
• Up to 98% purity with high recovery
• Isolated cells are untouched
Components
  • EasySep™ Human Naïve B Cell Isolation Kit (Catalog #17254)
    • EasySep™ Human Naïve B Cell Isolation Cocktail, 1 mL
    • EasySep™ Dextran RapidSpheres™, 1 mL
    • EasySep™ Isolation Cocktail Enhancer, 1 mL
  • RoboSep™ Human Naïve B Cell Isolation Kit (Catalog #17254RF)
    • EasySep™ Human Naïve B Cell Isolation Cocktail, 1 mL
    • EasySep™ Dextran RapidSpheres™, 1 mL
    • EasySep™ Isolation Cocktail Enhancer, 1 mL
    • RoboSep™ Buffer (Catalog #20104)
    • RoboSep™ Filter Tips (Catalog #20125)
Magnet Compatibility
• EasySep™ Magnet (Catalog #18000)
• “The Big Easy” EasySep™ Magnet (Catalog #18001)
• Easy 50 EasySep™ Magnet (Catalog #18002)
• EasyEights™ EasySep™ Magnet (Catalog #18103)
• RoboSep™-S (Catalog #21000)
Subtype
Cell Isolation Kits
Cell Type
B Cells
Species
Human
Sample Source
Leukapheresis, PBMC
Selection Method
Negative
Application
Cell Isolation
Brand
EasySep, RoboSep
Area of Interest
Immunology

Scientific Resources

Product Documentation

Document Type Product Name Catalog # Lot # Language
Document Type
Product Information Sheet
Product Name
EasySep™ Human Naïve B Cell Isolation Kit
Catalog #
17254
Lot #
Purchase date 2020-04-07 and later
Language
English
Document Type
Product Information Sheet 1
Product Name
RoboSep™ Human Naïve B Cell Isolation Kit
Catalog #
17254RF
Lot #
All other lots
Language
English
Document Type
Product Information Sheet 2
Product Name
RoboSep™ Human Naïve B Cell Isolation Kit
Catalog #
17254RF
Lot #
Purchase date 2020-04-07 and later
Language
English
Document Type
Safety Data Sheet 1
Product Name
EasySep™ Human Naïve B Cell Isolation Kit
Catalog #
17254
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Product Name
EasySep™ Human Naïve B Cell Isolation Kit
Catalog #
17254
Lot #
All
Language
English
Document Type
Safety Data Sheet 3
Product Name
EasySep™ Human Naïve B Cell Isolation Kit
Catalog #
17254
Lot #
All
Language
English
Document Type
Safety Data Sheet 4
Product Name
EasySep™ Human Naïve B Cell Isolation Kit
Catalog #
17254
Lot #
All
Language
English
Document Type
Safety Data Sheet 1
Product Name
RoboSep™ Human Naïve B Cell Isolation Kit
Catalog #
17254RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Product Name
RoboSep™ Human Naïve B Cell Isolation Kit
Catalog #
17254RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 3
Product Name
RoboSep™ Human Naïve B Cell Isolation Kit
Catalog #
17254RF
Lot #
All
Language
English

Educational Materials (11)

Brochure
Human B Cell Isolation Product Selection
Brochure
Isolate Human Immune Cells
Brochure
Tools For Your Immunology Research
Brochure
EasySep™ Cell Separation Technology
Wallchart
Frequencies of Cell Types in Human Peripheral Blood
Wallchart
Human Immune Cytokines
Video
How EasySep™ Magnetic Cell Separation Technology Works: Fast and Easy Cell Isolation
1:57
How EasySep™ Magnetic Cell Separation Technology Works: Fast and Easy Cell Isolation
Video
Isolate Cells with a Simple Pour-Off: EasySep™ Cell Separation Technology
1:13
Isolate Cells with a Simple Pour-Off: EasySep™ Cell Separation Technology
Video
Simultaneous Cell Isolation from Multiple Samples Using the EasyEights™ EasySep™ Magnet
0:57
Simultaneous Cell Isolation from Multiple Samples Using the EasyEights™ EasySep™ Magnet
Video
How to Isolate Cells with EasySep™ Column-Free Cell Separation Technology
1:23
How to Isolate Cells with EasySep™ Column-Free Cell Separation Technology
Video
How to Isolate PBMCs from Whole Blood Using Density Gradient Centrifugation (Ficoll™ or Lymphoprep™)
1:37
How to Isolate PBMCs from Whole Blood Using Density Gradient Centrifugation (Ficoll™ or Lymphoprep™)

Frequently Asked Question

Can EasySep™ be used for either positive or negative selection?

Yes. The EasySep™ kits use either a negative selection approach by targeting and removing unwanted cells or a positive selection approach targeting desired cells. Depletion kits are also available for the removal of cells with a specific undesired marker (e.g. GlyA).

How does the separation work?

Magnetic particles are crosslinked to cells using Tetrameric Antibody Complexes (TAC). When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a separate fraction.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Can EasySep™ be used to isolate rare cells?

Yes. We recommend a cell concentration of 2x108 cells/mL and a minimum working volume of 100 µL. Samples containing 2x107 cells or fewer should be suspended in 100 µL of buffer.

Are the EasySep™ magnetic particles FACS-compatible?

Yes, the EasySep™ particles are flow cytometry-compatible, as they are very uniform in size and about 5000X smaller than other commercially available magnetic beads used with column-free systems.

Can the EasySep™ magnetic particles be removed after enrichment?

No, but due to the small size of these particles, they will not interfere with downstream applications.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

For positive selection, can I perform more than 3 separations to increase purity?

Yes, the purity of targeted cells will increase with additional rounds of separations; however, cell recovery will decrease.

How does the binding of the EasySep™ magnetic particle affect the cells? is the function of positively selected cells altered by the bound particles?

Hundreds of publications have used cells selected with EasySep™ positive selection kits for functional studies. Our in-house experiments also confirm that selected cells are not functionally altered by the EasySep™ magnetic particles.

If particle binding is a key concern, we offer two options for negative selection. The EasySep™ negative selection kits can isolate untouched cells with comparable purities, while RosetteSep™ can isolate untouched cells directly from whole blood without using particles or magnets.
Read More

Product Applications

This product is designed for use in the following research area(s) as part of the highlighted workflow stage(s). Explore these workflows to learn more about the other products we offer to support each research area.

Data and Publications

Data

Starting with human PBMCs, the naïve B cell (CD3-CD19+CD27-) content of the isolated fraction is typically 94.9 ± 2.2% (mean ± SD). In the above example, the purities of the start and final isolated fractions are 7.1% and 97.7%, respectively.

Contact STEMCELL Technologies

Our Customer Service, Sales, and Product and Scientific Support departments in North America are available between 6 am and 5 pm Pacific Time (9 am and 8 pm Eastern Time). One of our representatives will be happy to help you by telephone or email. Please complete the form to contact us by email. A representative will get back to you shortly.
  •  

StemCell Technologies Inc. and affiliates ("STEMCELL Technologies") does not share your email address with third parties. StemCell Technologies Inc. will use your email address to confirm your identity and send you newsletters, transaction-related emails, promotional and customer service emails in accordance with our privacy policy. You can change your email preferences at any time.