EasySep™ Direct Human T Cell Isolation Kit

Immunomagnetic negative selection from whole blood kit
Catalog #
19661_C
Immunomagnetic negative selection from whole blood kit
From: 646 EUR
New look, same high quality and support! You may notice that your instrument or reagent packaging looks slightly different from images displayed on the website, or from previous orders. We are updating our look but rest assured, the products themselves and how you should use them have not changed. Learn more
Required Products
  1. EasySep™ Magnet
    EasySep™ Magnet

    Magnet for column-free immunomagnetic separation

  2. D-PBS Without Ca++ and Mg++
    D-PBS (Without Ca++ and Mg++)

    Dulbecco’s phosphate-buffered saline without calcium and magnesium

Overview

This cell separation kit can be used to isolate highly purified T cells directly from human whole blood by immunomagnetic negative selection.

This kit targets non-T cells for removal with antibodies recognizing specific surface markers. Unwanted cells are labeled with antibodies and EasySep™ Direct RapidSpheres™, and separated using an EasySep™ magnet. Desired cells are simply collected into a new tube and can directly be used for functional assays, flow cytometry or DNA/RNA extraction.
Advantages
• > 99.9% RBC depletion without the need for density gradient centrifugation, sedimentation, or lysis
• Up to 97% purity of isolated cells
• Fast, easy-to-use and column-free
• Isolated cells are untouched
Components
  • EasySep™ Direct Human T Cell Isolation Kit (Catalog #19661)
    • EasySep™ Direct Human T Cell Isolation Cocktail, 2 x 2.5 mL
    • EasySep™ Direct RapidSpheres™, 4 x 2.5 mL
  • RoboSep™ Human T Cell Isolation Kit with Filter Tips (Catalog #19661RF)
    • EasySep™ Direct Human T Cell Isolation Cocktail, 2 x 2.5 mL
    • EasySep™ Direct RapidSpheres™, 4 x 2.5 mL
    • RoboSep™ Buffer (Catalog #20104)
    • RoboSep™ Filter Tips (Catalog #20125) x 2
Magnet Compatibility
• EasySep™ Magnet (Catalog #18000)
• “The Big Easy” EasySep™ Magnet (Catalog #18001)
• Easy 50 EasySep™ Magnet (Catalog #18002)
• EasyEights™ EasySep™ Magnet (Catalog #18103)
• RoboSep™-S (Catalog #21000)
Subtype
Cell Isolation Kits
Cell Type
T Cells
Species
Human
Sample Source
Whole Blood
Selection Method
Negative
Application
Cell Isolation
Brand
EasySep, RoboSep
Area of Interest
Cell Therapy, Immunology

Scientific Resources

Product Documentation

Document Type Product Name Catalog # Lot # Language
Document Type
Product Information Sheet
Product Name
EasySep™ Direct Human T Cell Isolation Kit
Catalog #
19661
Lot #
18F92420 or higher
Language
English
Document Type
Product Information Sheet
Product Name
EasySep™ Direct Human T Cell Isolation Kit for RoboSep™
Catalog #
19661RF
Lot #
18F92420 or higher
Language
English
Document Type
Safety Data Sheet 1
Product Name
EasySep™ Direct Human T Cell Isolation Kit
Catalog #
19661
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Product Name
EasySep™ Direct Human T Cell Isolation Kit
Catalog #
19661
Lot #
All
Language
English

Educational Materials (15)

Brochure
Tools For Your Immunology Research
Brochure
EasySep™ Cell Separation Technology
Brochure
T Cell Reagents for Your Cellular Therapy Research
Brochure
Human T Cell Research Product Workflow
Brochure
EasySep™ Direct: Cell Isolation from Whole Blood in 20 Minutes
Technical Bulletin
High-Throughput Immunodensity-Based Cell Subset Isolation Directly from Whole Blood
Wallchart
Human Immune Cytokines
Wallchart
Frequencies of Cell Types in Human Peripheral Blood
Wallchart
Antigen Processing and Presentation
Video
Cell Isolation Directly from Whole Blood without RBC Lysis or Centrifugation: EasySep™ Direct
1:44
Cell Isolation Directly from Whole Blood without RBC Lysis or Centrifugation: EasySep™ Direct
Video
How to Isolate Cells Directly from Whole Blood Using the Easy 50 EasySep™ Magnet: 30-Minute Protocol
5:17
How to Isolate Cells Directly from Whole Blood Using the Easy 50 EasySep™ Magnet: 30-Minute Protocol
Video
How to Isolate Cells Directly from Whole Blood - EasySep™ Direct Protocol, EasyEights Magnet
6:13
How to Isolate Cells Directly from Whole Blood - EasySep™ Direct Protocol, EasyEights Magnet
Video
How to Isolate Cells Directly from Whole Blood Using the EasySep™ Purple/Silver Magnets
4:30
How to Isolate Cells Directly from Whole Blood Using the EasySep™ Purple/Silver Magnets
Video
Isolate Cells with a Simple Pour-Off: EasySep™ Cell Separation Technology
1:13
Isolate Cells with a Simple Pour-Off: EasySep™ Cell Separation Technology
Scientific Poster
Immunomagnetic Cell Isolation of Untouched Lymphocyte Populations Directly from Whole Blood
Load More Educational Materials

Frequently Asked Question

Can EasySep™ be used for either positive or negative selection?

Yes. The EasySep™ kits use either a negative selection approach by targeting and removing unwanted cells or a positive selection approach targeting desired cells. Depletion kits are also available for the removal of cells with a specific undesired marker (e.g. GlyA).

How does the separation work?

Magnetic particles are crosslinked to cells using Tetrameric Antibody Complexes (TAC). When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a separate fraction.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Can EasySep™ be used to isolate rare cells?

Yes. We recommend a cell concentration of 2x108 cells/mL and a minimum working volume of 100 µL. Samples containing 2x107 cells or fewer should be suspended in 100 µL of buffer.

Are the EasySep™ magnetic particles FACS-compatible?

Yes, the EasySep™ particles are flow cytometry-compatible, as they are very uniform in size and about 5000X smaller than other commercially available magnetic beads used with column-free systems.

Can the EasySep™ magnetic particles be removed after enrichment?

No, but due to the small size of these particles, they will not interfere with downstream applications.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

For positive selection, can I perform more than 3 separations to increase purity?

Yes, the purity of targeted cells will increase with additional rounds of separations; however, cell recovery will decrease.

How does the binding of the EasySep™ magnetic particle affect the cells? is the function of positively selected cells altered by the bound particles?

Hundreds of publications have used cells selected with EasySep™ positive selection kits for functional studies. Our in-house experiments also confirm that selected cells are not functionally altered by the EasySep™ magnetic particles.

If particle binding is a key concern, we offer two options for negative selection. The EasySep™ negative selection kits can isolate untouched cells with comparable purities, while RosetteSep™ can isolate untouched cells directly from whole blood without using particles or magnets.
Read More

Product Applications

This product is designed for use in the following research area(s) as part of the highlighted workflow stage(s). Explore these workflows to learn more about the other products we offer to support each research area.

Data and Publications

Data

Isolated T cells from whole blood obtained using EasySep™ Direct human T cell isolation kit

Figure 1. Typical EasySep™ Direct Human T Cell Isolation Profile

Starting with human whole blood from normal healthy donors, the typical T cell (CD3+) content of the non-lysed final isolated fraction is 95.3 ± 1.4% (gated on CD45) or 94.9 ± 1.5% (not gated on CD45). In the example above, the T cell (CD3+) content of the lysed whole blood start sample and non-lysed final isolated fraction is 33.0% and 95.0% (gated on CD45), respectively, or 33.0% and 94.9% (not gated on CD45), respectively. The starting frequency of T cells in the non-lysed whole blood start sample above is 0.059% (data not shown).

Contact STEMCELL Technologies

Our Customer Service, Sales, and Product and Scientific Support departments in North America are available between 6 am and 5 pm Pacific Time (9 am and 8 pm Eastern Time). One of our representatives will be happy to help you by telephone or email. Please complete the form to contact us by email. A representative will get back to you shortly.
  •  

StemCell Technologies Inc. and affiliates ("STEMCELL Technologies") does not share your email address with third parties. StemCell Technologies Inc. will use your email address to confirm your identity and send you newsletters, transaction-related emails, promotional and customer service emails in accordance with our privacy policy. You can change your email preferences at any time.