Extracellular Vesicle Sample Processing and Enrichment Strategies: Enabling Robust Analytical Readouts

Extracellular vesicles (EVs) are increasingly being investigated as biomarkers because they carry molecular cargo reflective of their cell or tissue of origin. However, variability in sample preparation and EV isolation can affect downstream analytical sensitivity, reproducibility, and interpretation.

In this webinar, Mandy Chan, Scientist, and Audrey Labrie, Product Manager for diagnostics, discuss key pre-analytical considerations for extracellular vesicle research and approaches for isolating and enriching EV populations from complex biological samples. Explore how immunomagnetic separation with EasySep™ enables high-purity EV isolation from diverse biofluids, supports compatibility with downstream assays, and allows targeted enrichment or depletion of specific EV populations.

In this webinar recording, you will learn how to:

  • Understand the role of pre-analytical sample preparation in extracellular vesicle biomarker workflows.
  • Compare key trade-offs associated with common extracellular vesicle isolation methods.
  • Use immunomagnetic separation to isolate EVs based on surface markers such as CD9, CD63, and CD81.
  • Work with EVs from diverse biofluids, including plasma, serum, urine, and conditioned media.
  • Prepare isolated EVs for downstream applications, including western blotting, transmission electron microscopy, flow cytometry, proteomics, and RT-qPCR.
  • Enrich target EVs or deplete abundant background populations (such as CD61+ platelet EVs) to improve detection sensitivity.
  • Capture specific EV subtypes using user-defined surface markers.

Webinar Transcript

Extracellular Vesicle Sample Processing and Enrichment Strategies: Enabling Robust Analytical Readouts

Audrey Labrie:
Hello, everyone, and thank you for joining us today for "Extracellular Vesicle Sample Processing and Enrichment Strategies: Enabling Robust Analytical Readouts."

While most EV analysis focuses on downstream platforms, the quality of your results is actually decided during sample processing. Today, we'll look at key pre-analytical strategies to ensure your data is robust and reproducible.

To briefly introduce ourselves, I'm Audrey, the Product Manager for the Diagnostics portfolio here at STEMCELL Technologies, and I'm joined by Mandy, an EV expert and Scientist on our Research and Development team.

Today, we'll start with an overview of extracellular vesicles, or EVs, as biomarkers and why pre-analytical standardization is critical. Then we'll look at EasySep™ EV isolation data across biofluids, explore targeted strategies such as platelet depletion, and wrap up with some key takeaways.

Over the last decade of liquid biopsy advances, we've realized that the immunomagnetic principles that transformed cell isolation can overcome the main bottlenecks in EV biomarker discovery today.

I'd like to start with a brief introduction to liquid biopsies and extracellular vesicles. Liquid biopsies let us capture real-time disease data directly from body fluids such as blood. By analyzing circulating tumor cells, cell-free DNA, or EVs, we can get a non-invasive, holistic picture without the sampling limitations of a physical tissue biopsy. Liquid biopsy doesn't replace traditional tissue assays; it complements them. Today, we're focusing on EVs, their potential as biomarkers, and opportunities for realizing their clinical validation.

EVs are lipid-bound vesicles ranging from 30 nanometers to 5 microns and are produced by virtually all cells. As they form, they package and protect proteins, RNA, and DNA inside a lipid bilayer. They then travel through body fluids to target cells, where they can deliver this cargo and drive functional changes.

So why are EVs such compelling biomarkers? First, they're far more abundant in plasma than circulating tumor cells. Second, their lipid membrane protects delicate internal cargo from degradation. Third, surface proteins mirror the membrane phenotype of their parent cell. Finally, their cargo shifts in real time as cells transition from healthy to diseased. Together, these characteristics make EVs a very compelling source of information for biomarker discovery and development.

Because of these advantages, biomarker research involving EVs has surged. Annual publications focusing on EV-derived biomarkers now exceed the combined totals of cell-free DNA, circulating tumor cells, and tumor-informed platelets.

However, despite this research boom, translation into approved clinical diagnostic tests remains disproportionately low. This illustrates the translational lag. While over 1,000 active clinical trials utilize cell-free DNA, fewer than 500 utilize EVs, and only a handful of EV-based assays are currently undergoing clinical validation.

Clinical validation requires binary or quantifiable markers detected by highly sensitive and specific assays using workflows that are accessible to routine diagnostic laboratories.

Multiple publications have addressed barriers to the translation and clinical validation of EV biomarkers in liquid biopsy. One publication points to pre-analytical considerations as key contributors to attrition in EV biomarker clinical validation. Specifically, the authors cite variability in EV isolation outputs introduced by ultracentrifugation, suboptimal purity, and the need for technical expertise and specialized equipment. We'll speak more about EV isolation methods in the next slides.

The authors also highlight the limited sensitivity of assays using EVs isolated in bulk. Biofluids such as plasma contain EVs from throughout the body, which can mask or wash out the analytical readout from the tissue-derived EVs of interest.

Traditional EV isolation methods all have trade-offs. Ultracentrifugation is historically the gold standard, but protocols can take anywhere from 3 to 90 hours, with variable yield and purity. Size-exclusion colums, or SEC, provides cleaner bulk preparations but still gives you a mixed population. Precipitation offers high recovery but co-isolates contaminants such as protein aggregates. Most importantly, none of these bulk approaches allows you to target specific cell origins. Immunoaffinity platforms such as EasySep™ change that by using surface markers to isolate specific EV subpopulations, giving you a more targeted and biologically relevant readout.

Now let me turn to our second section: sample preparation and pre-analytical considerations. We'll highlight how target enrichment in blood and bone marrow sets the foundation for diagnostic sensitivity and how these concepts directly apply to EVs.

EasySep™ cell separation has been incorporated into a number of lab-developed tests that support a variety of clinical diagnostic applications, including lineage-based chimerism testing, crossmatch analysis, and plasma cell enrichment upstream of diagnostics for multiple myeloma.

In the context of the diagnostic assay workflow, EasySep™ products are used during the pre-analytical phase as a biological enrichment step for cells of interest, typically from blood or bone marrow. Depending on the assay, this enrichment step may precede a subsequent bioanalyte extraction step, such as for DNA, RNA, or proteins, or enriched cells may be used directly in assay preparation and execution.

The key point is that pre-analytical sample preparation is the foundation of a robust and reliable diagnostic workflow and can account for 46% to 68% of errors in diagnostic testing.

As efforts continue to push precision medicine forward, the need for sample-processing solutions that enable high-resolution, high-sensitivity diagnostic assays is only increasing. Demonstrating our commitment to clinical translation, in 2024 STEMCELL received FDA de novo classification of the EasySep™ Human Bone Marrow CD138 Positive Selection Kit as a Class II IVD medical device for the enrichment of plasma cells upstream of validated diagnostic assays for multiple myeloma.

This enrichment step has been demonstrated to increase both the sensitivity and depth of analysis by increasing the frequency of the cells of interest.

Pre-analytical enrichment is critical when working with low-frequency targets or rare disease samples. EasySep™ is like finding a needle in a haystack: using positive selection or targeted depletion to concentrate your analyte. We're now applying these same cell-enrichment strategies to streamline EV biomarker discovery and translation.

Building on our expertise in cell enrichment for clinical diagnostics, we've extended the EasySep™ platform to EV isolation, providing the advantages listed on this slide. Beyond developing these tools, driving clinical adoption requires industry-wide collaboration on pre-analytical best practices. While societies such as the International Society for Extracellular Vesicles, or ISEV, focus on foundational EV biology, consortia such as BLOODPAC have been remarkably effective at aligning industry, regulatory, and clinical partners to standardize liquid biopsy workflows.

As active members, we see a valuable opportunity to help bridge pre-analytical standardization efforts and accelerate the clinical validation of EV-derived biomarkers.

With that context, I'll hand things over to Mandy to walk through the technical performance of EasySep™ EV isolation.

Mandy Chan:
In this part of our talk, I'm going to show you how EasySep™ compares with other traditional EV isolation methods and how it fits into a typical workflow.

EV isolation methods come with varying levels of recovery and specificity. High-recovery methods such as precipitation have low purity. The most commonly used methods, such as size-exclusion chromatography and differential ultracentrifugation, have intermediate recovery and specificity. High-purity methods such as immunoprecipitation often have low recovery, which is a major pain point for EV isolation.

In the past few years, we've developed an immunomagnetic separation method called EasySep™ that provides high purity and better recovery than differential ultracentrifugation and SEC.

EasySep™ captures EVs using their surface markers. Our EasySep™ Pan-EV Kit captures EVs using the tetraspanins CD9, CD63, and CD81. The kit uses antibody complexes and magnetic particles to label EVs for magnetic separation.

After labeling the EVs with antibodies and particles, the labeled EVs are incubated in one of our EasySep™ magnets. Unwanted contaminants are poured off, and the positively selected EVs are washed a few more times in the magnet and finally resuspended for downstream applications. The total protocol time is less than 30 minutes.

Before showing our data, I'd like to share an example of the EasySep™ Pan-EV Kit being used in a clinical laboratory setting, published by McNamee and colleagues in Translational Oncology. In their publication, the authors aimed to identify an isolation method with high EV purity that was also quick, cost-effective, and translatable to a clinical setting.

They compared six different EV isolation methods: differential ultracentrifugation, PEG precipitation, nickel-based isolation, SEC columns, and two different immunomagnetic isolation kits, including the EasySep™ Pan-EV Positive Selection Kit.

In the study, they used each of these six methods to isolate EVs from breast cancer and age-matched control serum pools. They then analyzed the isolated EVs from each method by western blot, ELISA, particle size, protein concentration, and EV structure. From this, they selected what they considered to be the best method, analyzed sera from 20 breast cancer patients and controls, and identified a potential blood-based biomarker.

The recovery and purity results obtained with each of the six methods are summarized here. The authors looked at EV recovery using CD63, CD9, and CD81 by western blot. They also looked at the contaminants albumin by western blot and ApoB by ELISA.

EasySep™ provided very competitive recovery for CD63, CD9, and CD81 as measured by western blot. What stands out is that EasySep™ had the lowest albumin level and the lowest ApoB signal among the methods compared. The combination of low albumin and low ApoB indicates that EasySep™ provided the highest EV purity among the methods evaluated in the paper.

McNamee and colleagues stated that among the six methods evaluated, some could not readily be advanced to clinical settings because of their complexity, the need for specialized equipment, and the length of time required. The authors suggested that the EasySep™ Human Pan-EV Kit was the most suitable for routine clinical diagnostic use.

After choosing the best method, the authors moved forward with the EasySep™ Pan-EV Kit to isolate EVs from 20 breast cancer patients and 20 control serum samples.

The isolated EVs were lysed and measured using two techniques that could readily be performed in a typical diagnostic laboratory. Protein concentration was measured using the Bradford assay and taken as a surrogate for EV quantification. ELISA was used to measure Gremlin-1, a potential biomarker implicated in the metastasis of breast cancer to the lungs.

As you can see from the graph on the left, significantly greater amounts of EVs were present in sera from cancer patients compared with healthy age-matched controls. On the right, significantly greater levels of Gremlin-1 were observed in the EVs from breast cancer patients as well.

While the work highlighted the potential of Gremlin-1 as a breast cancer biomarker, perhaps even more relevant was the authors' ability to identify an EV isolation method—EasySep™—that was simple enough to use in a clinical laboratory setting.

That paper demonstrated that EasySep™ can be used with serum samples in a clinical setting. In our own work, we've shown that EasySep™ can also isolate EVs from plasma, serum, urine, and conditioned cell culture media from mesenchymal stromal cells, organoids, and cancer cells. We also have a technical bulletin on isolating EVs from urine available online.

We've shown that EasySep™ is compatible with many common diagnostic assays for protein and nucleic acid analysis, including western blot, transmission electron microscopy, proteomics, and RT-qPCR. EV sizing, counting, and phenotyping by flow cytometry can also be performed after releasing the magnetic particles from the isolated EVs.

With the EasySep™ method, magnetic particles remain attached to the EVs after positive selection. One common question we receive is whether those particles can be removed. It is possible, but for many diagnostic assays, particle removal may not be necessary, particularly if the method involves lysing the EVs and extracting proteins or nucleic acids, because the particles are removed during the extraction steps.

Particle removal is therefore optional. At the moment, the release protocol is not published in our Instructions for Use, but it is available upon request from our Product and Scientific Support team.

Hopefully, I've convinced you that the EasySep™ Pan-EV Kit works well for isolating EVs from many types of samples. However, there are still challenges in the field around standardized methods for isolating EVs. As shown in the MIBlood-EV publication, after total EVs are isolated from a sample, platelet-derived EVs and platelets remain major confounders for downstream assays.

To address this issue, we developed an EasySep™ kit that targets the CD61 surface marker, which is expressed on platelet-derived EVs. In this kit, CD61-positive EVs are first labeled with an antibody cocktail and magnetic particles and then magnetically removed from the sample. The supernatant is poured off and can be used directly for downstream assays, or the CD61-negative EVs can be further isolated using other methods such as the Pan-EV Kit or SEC columns. The protocol takes only 15 minutes and can be readily incorporated into an existing workflow.

We applied this new EasySep™ method to deplete CD61-positive EVs from 1 mL of plasma and then recaptured the remaining EVs using the EasySep™ Pan-EV Kit. On average, 95% of CD61-positive EVs were depleted from the plasma sample compared with the no-depletion control.

CD63 and CD9 are also expressed on platelet-derived EVs, so we expected those signals to decrease when platelet EVs were removed, as shown by the dimmer signals in the middle. Recovery of non-platelet EVs was not affected by depletion, as shown by the similar intensity of CD81-positive EVs in the bottom blot.

We expect that removing platelet EVs can improve detection of lower-abundance EVs. Here, we took plasma EVs prepared by differential ultracentrifugation, performed EasySep™ CD61 depletion, and analyzed the same number of EVs from samples before and after depletion. After depletion, the CD61 signal was no longer detected and the CD81 signal increased.

When we compared the ratio of non-platelet EVs to platelet EVs, represented by the CD81:CD61 ratio, it increased from 0.2 before depletion to 4.4 after depletion. This shows that depleting platelet EVs can improve detection of lower-abundance EV populations.

The EasySep™ CD61 Kit can also be used both to positively select CD61-positive platelet EVs and to deplete platelet EVs from the same sample. Here, we performed platelet-EV depletion as before but retained the magnetically labeled EVs that remained in the magnet. We further washed these positively selected platelet EVs and then released them from the particles for flow cytometry, counting, and functional analyses.

Here are representative flow plots showing EVs in untreated plasma, platelet-EV-depleted plasma, EasySep™-isolated platelet EVs, and total EVs isolated by differential ultracentrifugation. EasySep™ successfully depleted platelet EVs from plasma, and the positively selected EVs had higher CD41 purity than EVs isolated by ultracentrifugation.

The number of EVs present in the depleted plasma was significantly lower than in untreated plasma, while the number of platelet EVs recovered by the EasySep™ kit was, on average, higher than with differential ultracentrifugation.

Next, we subjected the EasySep™-isolated CD61-positive platelet EVs to a fibroblast wound-healing assay to determine whether they retained the ability to improve wound healing. On the left are representative gap-closure images over 48 hours, with data from three donors summarized in the graph on the right. EasySep™-isolated EVs increased gap closure compared with the reagent-only and basal-medium-only controls.

So far, we've shown that EasySep™ can be used to isolate Pan-EVs and to deplete or positively select platelet EVs. But what if you've discovered a new biomarker and want to specifically isolate that EV subtype?

To do this, we've developed the EasySep™ Extracellular Vesicle PE Positive Selection Kit, which allows you to indirectly isolate EVs using a surface marker of your choice. The EVs of interest are first labeled with a specific, user-chosen PE-labeled antibody. An antibody complex that binds the PE fluorophore is then added, which in turn binds the magnetic particle for EasySep™ separation.

We used this indirect EasySep™ method to isolate both immune cell-derived and cancer cell-derived EVs from a mock patient plasma sample. We then performed western blots using common EV markers and EV-subtype-specific markers.

In the first lane, the EasySep™ method was highly specific: immune cell-derived EVs were captured by targeting CD45. These EVs were also positive for the tetraspanins CD9, CD63, and CD81. In the second lane, cancer cell-derived EVs were captured by targeting EpCAM, and these EVs were weakly positive for the tetraspanins.

An added benefit of this EasySep™ method is that you can include an isotype-control PE-labeled antibody to demonstrate that the observed signals are not due to nonspecific binding to the EasySep™ reagents. As shown in the third lane, there was no signal in the isotype-control isolation.

In addition to being highly specific, EasySep™ continued to outperform differential ultracentrifugation for recovery of the targeted EV subtypes, as shown by the higher CD45 and EpCAM signals observed.

This EasySep™ method can also be used to isolate EVs from non-human species. When working with species such as mice, sample volume can be very limited. Our EasySep™ positive-selection kits can be used with an EasyPlate™ magnet and a 96-well plate to perform isolations from volumes as small as 50 µL.

As a proof of principle, we isolated mouse CD63-positive EVs from mouse plasma using our EasyPlate™ magnet. We obtained a strong CD63 signal while maintaining low nonspecific binding in the isotype control.

Finally, we've optimized the EasySep™ method on two automated platforms, RoboSep™-S and RoboSep™-16, which can process up to 4 or 16 samples, respectively. The instruments are simple to use: you load the instrument and walk away. Isolations are completed in well under two hours, depending on the instrument and the number of samples being run.

We expect automation to reduce user variability and improve performance. With RoboSep™-S and RoboSep™-16, we saw EV recovery equivalent to the manual method, along with a significant reduction in co-isolated albumin, further improving the purity of the isolated EVs.

I'll pass things back to Audrey.

Audrey Labrie:
Thank you, Mandy. With that, we've reached our final section for today.

To wrap up today's presentation, let's revisit our main summary points. First, sample enrichment matters: upstream sample preparation directly impacts both the sensitivity and robustness of your entire downstream analytical workflow.

Second, we need to overcome key barriers stalling the clinical translation of EV biomarkers. We've listed three of them on the slide.

Third, accessible and standardized workflows are important. EasySep™ EV Positive Selection Kits address these pre-analytical hurdles by providing an accessible, fast workflow that enables targeted EV isolation, with automated options on RoboSep™-S and RoboSep™-16 to further support standardization and inter-laboratory reproducibility.

Thank you so much for watching. If you have any questions about the data presented today or would like to learn more about EasySep™ for your research, please reach out to our team or visit stemcell.com.

Have a great day!