Negative Selection Columns, Pump Feed Kit

? 1.800.667.0322   > Contact Us

StemSep® Equipment



Free from STEMCELL

  • 1.0 in Column Pump Feed Kit
  • 0.6 in Column Pump Feed Kit
  • 0.5 in Column Pump Feed Kit
  • 0.3 in Column Pump Feed Kit
  • 0.1 in Column Pump Feed Kit
  • Label for 0.1" Negative Selection Columns Pump Feed Kit 1 Kit
  • Label for 0.3" Negative Selection Columns Pump Feed Kit 1 Kit
  • Label for 0.5" Negative Selection Columns Pump Feed Kit 1 Kit
  • Label for 0.6" Negative Selection Columns Pump Feed Kit 1 Kit
  • Label for 1.0" Negative Selection Columns Pump Feed Kit 1 Kit
1.0 in Column Pump Feed Kit
StemSep® Negative Selection Columns for Pumps are available in five sizes.
• High-gradient magnetic columns comprised of stainless steel mesh
• High capacity columns designed for negative selection
• Cell range from 1 x 10e5 - 2 x 10e10 cells depending on the column
• Positive selection reagents are designed for use with commercially available magnetic positive cell selection columns
Product Name Description Catalog # Size Price Quantity
0.1" Negative Selection Columns For 1 x 10e5 - 2 x 10e7 cells 12022 10 Columns 127.00 USD      
 Save Item
0.3" Negative Selection Columns For 2 x 10e7 - 1 x 10e8 cells 12032 10 Columns 188.00 USD      
 Save Item
0.5" Negative Selection Columns For 5 x 10e7 - 3 x 10e8 cells 12052 10 Columns 282.00 USD      
 Save Item
0.6" Negative Selection Columns For 1 x 10e8 - 1.5 x 10e9 cells 12062 10 Columns 564.00 USD      
 Save Item
1.0" Negative Selection Column for 2 x 10e9 - 2 x 10e10 cells 12470 1 Column 144.00 USD      
 Save Item

Order Offline:

Call us: +1.604.877.0713  
Toll Free: 1.800.667.0322  
Email us:
 
Fax us: +1.604.877.0704
Toll Free Fax: 1.800.567.2899

Recommended for:
• StemSep® Black Magnet (Catalog #11070)
• StemSep® Blue Magnet (Catalog #11060)
• StemSep® Green Magnet (Catalog #11050)
• StemSep® Red Magnet (Catalog #11030)
Intended Use Statement: For Research Use Only. Not for Therapeutic or Diagnostic Use.
Equipment Required:
StemSep® Pump Feed (Catalog #12022, 12032, 12052, 12062, 12470)
Product Type: Cell isolation products
Popular Product Line: StemSep
Area of Interest: Immunology
Cell Isolation Product Type: Equipment

Procedures and instruction manuals:

Educational resources:

FAQS:


  • Question: What is the function of EDTA in the buffer?

    Answer: EDTA prevents cells such as monocytes from adhering to the column. The effective concentration is 1–2 mM.


  • Question: Do buffers need to be degassed prior to doing StemSep®? No.

    Answer: Degassing the buffer is no necessary.


  • Q. CAN STEMSEP® COLUMNS BE USED FOR POSITIVE SELECTION?

    A. No. Our positive selection reagents can be used with commercially available positive selection columns.

  • Q. CAN I USE STEMSEP® ON REAGENTS OTHER MAGNETIC CELL SEPARATION SYSTEMS?

    A. Because of the extremely small size of the StemSep® magnetic colloid (50-150 nm), we have found that StemSep® reagents are completely compatible with any magnet of strength equal or greater than 0.5 Tesla. Many customers have reported that their results have been equivalent or better with the economical StemSep® reagents.

  • Q. WHICH SPECIES CAN STEMSEP® BE USED WITH?

    A. Cocktails have been optimized for the selection of human, mouse, rat and non-human primate samples.

  • Q. SHOULD MY PRIMING BUFFER CONTAIN PROTEIN?

    A. The priming medium should not contain protein. Use PBS, either at room temperature or degassed, without serum or other protein to prime the column from bottom up. However, the separation medium used to wash the column prior to use will contain protein.

  • Q. WHAT IS THE BENEFIT OF USING A PUMP?

    A. The benefit is twofold: 1) It can allow up to four simultaneous separations to be performed when used in conjunction with the blue magnet (#11060). 2) It can improve purity and recovery when larger columns are used.

  • Q. WHAT CONCENTRATION SHOULD CELLS BE SUSPENDED AT PRIOR TO SEPARATION?

    A. A cell concentration of 2-8 x 107 is acceptable. If using 1.0" columns with human cells, the cell concentration is increased to 108 cells/mL.

  • Q. ARE THERE ANY SUGGESTIONS FOR CLUMPY SAMPLES?

    A. Yes. There are several reasons a sample might clump.
    1) If the cells were frozen or poorly stored then DNA from dead cells can form clumps. If this is the case adding DNAse to the cell suspension may help.
    2) The presence of Ca++/Mg++ in the medium may cause cells, such as monocytes, to clump. Ca++/Mg++ free PBS should be used. EDTA can also be used to decrease clumping.
    3) Cells may clump if they become activated. Keeping the cells at 4°C or on ice can prevent this.

  • Q. WHAT IS THE FUNCTION OF EDTA IN THE BUFFER?

    A. EDTA prevents cells such as monocytes from adhering to the column. The effective concentration is 1–2 mM.

  • Q. DO BUFFERS NEED TO BE DEGASSED PRIOR TO DOING STEMSEP®?

    A. No. Degassing the buffer is not necessary.

  • Q. WHY IN THE STEMSEP® MANUAL IS IT SUGGESTED TO AVOID DEXTRAN SEDIMENTATION?

    A. Our particles are coated with dextran, so if the free dextran is not washed away completely there could be some interference with colloid binding. HetaSep sedimentation is a good alternative to dextran. Please see the HetaSep protocol.

  • Q. CAN THE STEMSEP® COLUMNS BE REUSED?

    A. Yes, we have found that the columns can be reused up to six times without a decrease in performance, see protocol for Reusing StemSep Columns.

  • Q. CAN THE CELLS THAT WERE RETAINED IN THE COLUMN BE REMOVED?

    A. No. Since our columns bind labeled cells so strongly, it is difficult to remove cells from the column even after the column is removed from the magnet.

  • Q. WHY IS IT SUGGESTED THAT THE ANTI-CD32 ANTIBODY BE USED WHEN ISOLATING MONOCYTES?

    A. Monocytes may non-specifically bind tetramers via the Fcg RIIA on their surface, and subsequently be retained on the column. To decrease this non-specific binding, cells should be incubated with an anti-CD32 blocking reagent (Catalog #14531, #14551, and #14561) prior to immunomagnetic labeling. To use, follow the instructions in the StemSep®  Operating Manual.

Product Name

Description

Catalog #

4 Channel Peristaltic Pump StemSep® Equipment 11000